| To: | towertalk@contesting.com |
|---|---|
| Subject: | Re: [TowerTalk] Metal Roof |
| From: | Jim Brown <jim@audiosystemsgroup.com> |
| Reply-to: | jim@audiosystemsgroup.com |
| Date: | Thu, 11 Jan 2018 10:59:42 -0800 |
| List-post: | <mailto:towertalk@contesting.com> |
Hi Skip,The "interference" is probably passive intermod (rectification at one or more joints in that roof) that is generating a spur on the input frequency of the repeater. If this is the cause, the joint(s) must be bonded at multiple points. 73, Jim K9YC On 1/11/2018 10:29 AM, Gilbert Kauffmann wrote: My repeater is desensed. _______________________________________________ _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |
| <Prev in Thread] | Current Thread | [Next in Thread> |
|---|---|---|
| ||
| Previous by Date: | Re: [TowerTalk] S21 to Rp & Cp - Equivalent Circuit, jimlux |
|---|---|
| Next by Date: | Re: [TowerTalk] Metal Roof, Kent Olsen |
| Previous by Thread: | Re: [TowerTalk] Metal Roof, Gilbert Kauffmann |
| Next by Thread: | Re: [TowerTalk] Metal Roof, Kent Olsen |
| Indexes: | [Date] [Thread] [Top] [All Lists] |