Check the Rohn catalog, link is in the previous post for guy requirements. (3
sets of guys for 100'?)
The pier pin sets into a hole drilled into the concrete and the base plate has
a hole in the middle that sets over the pin. No 'hard' connection. Some use
epoxy to set the pin, mine was pretty snug and I just tapped the pin into the
concrete.
Fred KC5YN
On Tuesday, January 9, 2018 10:31 PM, RCM <robrk@nidhog.net> wrote:
> On Jan 9, 2018, at 23:19, W1JCW John <W1JCW@hotmail.com> wrote:
>
> Going to install 100' of rohn 45.
>
> Questions I have are:
>
> Demensions of the base hole 6' x 3'
> Size of rebar cage
> Guys supports at 33' 66' ect at what angle and how far away from the base
> Was going to install piers encase in concrete
>
> Ideas suggestions for this type of installation would be appreaciated
>
> I have the pier base how does that secure to the base
>
> 73-
> W1JCW
> John
>