Towertalk
[Top] [All Lists]

Re: [TowerTalk] Fwd: Grounding connection to tower legs

To: towertalk <towertalk@contesting.com>
Subject: Re: [TowerTalk] Fwd: Grounding connection to tower legs
From: Steve Maki <lists@oakcom.org>
Date: Mon, 16 Oct 2017 08:45:16 -0400
List-post: <mailto:towertalk@contesting.com>
Commercial tower grounds are almost always cad-welded, but usually to the heavy base flange(s), or to heavy tabs already welded to the tower expressly for the purpose of grounding.

I've seen some cad-welds on *solid* legs, but I can't recall any on pipe legs.

-Steve K8LX

On 10/16/2017 8:26 AM, Ward Silver wrote:

I also got a question about CadWeld and those are great for ground
electrodes but I would never use them on the tower itself.  It may be
possible to safely weld a connection to a tower but I wouldn't do it to a
tubular load-bearing leg, not to mention the dissimilar metals involved and
all that. I wouldn't want to weaken a cross-brace either, especially when
there are other options designed for that exact application. Maybe someone
with broadcast tower experience could weigh in on that.  I repeat, for us
hams, just buy the right stuff and and do what the manufacturer says.

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>