“With no preventative You have to twist the bolt off.  That can be a real 
knuckle buster with 3/8ths or 1/2".

That’s if you are lucky.  Often the bolt will not twist and the bolt head 
shears and then snaps off necessitating cutting off the bolt with a hacksaw, 
usually in a VERY difficult and compromising position on the tower with poor 
physical access to the bolt!

Neverseize or similar compounds are not a panacea either but they greatly 
increase the odds of a successful outcome.  Don’t use too much though of else 
you will get it all over you when you put it on or when you take it off.  Aside 
from the permanent staining of your clothes, the slipperiness of the compound 
will compromise your ability to do tower work before you are able to wipe it 
off your hands, gloves, tools, etc.  I suggest that you put a large, soft cloth 
in your tool bag on the tower.  If you are not on the tower bring a cloth 
and/or paper towels to wipe off the excess when you apply it and to wipe off 
the bolt and hardware when you unbolt it.

Clean = safer and more productive tower work.

73

Bob , KQ2M

From: Roger (K8RI) on TT 
Sent: Sunday, July 02, 2017 9:29 AM
To: towertalk@contesting.com 
Subject: Re: [TowerTalk] Galling and seizing of SS nuts to SS threaded studs 
and bolts.

Easier than that. Just use Neverseize(sp)
SS to SS under tension, or just tight fitting will have the nut bonding 
to the bolt.
With no preventative You have to twist the bolt off.  That can be a real 
knuckle buster with 3/8ths or 1/2". Been there, done that.

73, Roger (K8RI)

On 7/2/2017 Sunday 8:27 AM, J Chaloupka via TowerTalk wrote:
> I have often read where there is a problem of the threads of SS assemblies 
> becoming seized or locked together after a time in the weather and becoming 
> difficult and or useless when disassembly and reassembly is required.It is my 
> opinion that one can use bronze nuts with the stainless threaded component 
> with no such galling occurring. It is something I have done for years with no 
> trouble.Opinions welcome.JIM, W4QBQ
> _______________________________________________
>
>
>
> _______________________________________________
> TowerTalk mailing list
> TowerTalk@contesting.com
> http://lists.contesting.com/mailman/listinfo/towertalk


-- 

73

Roger (K8RI)


---
This email has been checked for viruses by Avast antivirus software.
https://www.avast.com/antivirus


_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
<Prev in Thread] Current Thread [Next in Thread>