Towertalk
[Top] [All Lists]

Re: [TowerTalk] Antenna & Tower Wind Load Ratings

To: towertalk@contesting.com
Subject: Re: [TowerTalk] Antenna & Tower Wind Load Ratings
From: jimlux <jimlux@earthlink.net>
Date: Fri, 16 Jun 2017 18:25:10 -0700
List-post: <mailto:towertalk@contesting.com>
On 6/16/17 7:53 AM, Jim Thomson wrote:
The below url pdf explains the 222-G spec in detail.
http://www.towernx.com/downloads/TIA-222-G_Explained.pdf



t explains it but doesn't have all the various K factors, which in turn are from a whole bunch of tables.

For instance 2.6.5.2
Velocity Pressure Coefficient
Kz = 2.01(z/zg)^(2/alpha)
Kzmin <= Kz <= 2.01

z = height above ground level at base of structure
zg, alpha, and Kzmin are tabulated in Table 2-4

Exposure category B , Zg = 1200ft, alpha =7.0, Kzmin = 0.70, Ke=0.90, etc.


2.6.6.4 Topographic factor
Kzt = (1+ (Ke*Kt/Kh)^2

Kh = height reduction factor
 = exp(f*z/H)
Ke = terrain constant in Table 2-4
Kf = topographic constant in Table 2-5
f = height attenuation factor given in Table 2-5
z = height above ground level at base of structure
H = height of crest above surrounding terrain


and on and on.