1/2" and 3/4" EMT is designed with an alloy that is easily bendable. It's likely the larger sizes use the same alloy. IOW a bad choice for a Gin Pole. I purchase 2" 6061-T6 with 0.25" wall (mill finish) that comes in stock lengths of 24, half dozen at a time. They deliver right to my shop door for no extra charge.'. I use it for masts and gin poles.

I'd need to call for current prices

73, Roger (K8RI)


On 3/24/2017 5:03 PM, Jim Brown wrote:
The steel used for electrical conduit, even heavy-wall, is not designed for mechanical strength, and is probably a poor choice for use as a gin pole.

73, Jim K9YC

On Fri,3/24/2017 12:51 PM, Ed Stallman wrote:
I was looking at EMT but I see the wall thickness is .065