It's worth remembering that the equations involve _vector_ sums. So just because the current _amplitudes_ in the two legs of a TL might be equal in the two directions, it doesn't mean they are balanced and that the CM current is zero.

Several commercial balance meters get that wrong!

Steve G3TXQ


On 21/03/2017 15:00, Máximo EA1DDO_HK1H wrote:
Hi Jim,


I think I've got it.


If I3=0, I1 & I2 are always same value.

Any imbalance is always when I3 different than 0.


I really appreciated your help on that.


Thank you very much


73, Maximo