Thanks.
My copy doesn't show if the coax not fed is grounded or open. At least
I haven't found it.
73, Roger (K8RI)
On 3/10/2017 10:48 PM, jimlux wrote:
On 3/10/17 6:02 PM, Roger (K8RI) on TT wrote:
Doesn't the added inductance of a choke that covers 80, or 40 also add
more than just the length of the coax?
There's no inductance contributed to the signal being carried, because
the magnetic field from the inner conductor is exactly cancelled by
the inductance of the current in the shield. Just like a bifilar
winding on a non-inductive wirewound resistor.
now, for the current on the *outside* of the coax, yep there's
inductance a-plenty.
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
--
73
Roger (K8RI)
---
This email has been checked for viruses by Avast antivirus software.