I was going to keep the 10 and 40 meter tower closer to the house and 15and
20@ 500 feet away
Sent from my iPhone
> On Feb 12, 2017, at 4:59 PM, Ed Sawyer <sawyered@earthlink.net> wrote:
>
> There is really no good substitute for low loss feedlines than hardline.
> Hardline uses a lot of copper and copper is not cheap (getting more
> expensive recently). An alternative would be to mount an amplifier at the
> base of the tower and accept the losses getting to it.
>
>
>
> LDF5-50 seems to be the best compromise for cost and workability. The LDF7
> is very hard to work with but does provide even lower loss. 0.06dB per 100
> ft on 28Mhz difference. If it's a 500 ft run to the tower, its 0.3dB.
>
>
>
> I have 2 LDF5-50 runs from the house to the 1st tower that are 300ft. Then
> another 150 ft to tower 2 (also all LDF5-50). LDF4 up the tower on 10 - 40
> Meters.
>
>
>