I use Andrews Heliax for all my feedlines, with N connectors - including HF
bands.
Line loss is negligible.
Power handling, minimum 5kW.
Thanks,
James
ki5dq
--------------------------------------------
On Tue, 12/20/16, Mike Fahmie via TowerTalk <towertalk@contesting.com> wrote:
Subject: Re: [TowerTalk] Double Coax Runs to Reduce Loss?
To: "Tom Osborne" <w7why1@gmail.com>, "towertalk@contesting.com"
<towertalk@contesting.com>
Date: Tuesday, December 20, 2016, 10:10 PM
You'd still need to match the 25Ω line to your 50Ω source.
From: Tom Osborne <w7why1@gmail.com>
To: towertalk@contesting.com
Sent: Tuesday, December 20, 2016 8:04 PM
Subject: Re: [TowerTalk] Double Coax Runs to Reduce Loss?
So - could this be used to fee a ground mounted vertical? 73
Tom W7WHY
On Tue, Dec 20, 2016 at 8:59 AM, <lstoskopf@cox.net> wrote:
> So, neglecting the I/R loss issue.....how does he match for the 26 ohm coax
> he has created?
>
> N0UU
>
>