Towertalk
[Top] [All Lists]

Re: [TowerTalk] Crank up tower lightning protection

To: towertalk@contesting.com
Subject: Re: [TowerTalk] Crank up tower lightning protection
From: "Roger (K8RI) on TT" <K8RI-on-TowerTalk@tm.net>
Date: Wed, 12 Oct 2016 11:14:42 -0400
List-post: <towertalk@contesting.com">mailto:towertalk@contesting.com>
Each section will have one, or possibly two pads making contact.

73

Roger (K8RI)

On 10/12/2016 Wednesday 7:12 AM, David Robbins wrote:
You already have the tower cabling and the coax and control wires going from
top to bottom.  And as far as lightning is concerned the tiny gap between
sections, even if there isn't a metallic connection, isn't going to mean
anything to lightning.  When figuring lightning protection for high voltage
power lines we ignored the insulators that were sometimes used on the shield
wires to break them up to prevent 60hz circulating currents because they
would flashover almost instantly from any lightning event... and those had
gaps of several inches.

David Robbins K1TTT
e-mail: mailto:k1ttt@arrl.net
web: http://wiki.k1ttt.net
AR-Cluster node: 145.69MHz or telnet://k1ttt.net:7373

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk


--

73

Roger (K8RI)


---
This email has been checked for viruses by Avast antivirus software.
https://www.avast.com/antivirus


_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>