If the tower is being used as a vertical radiator and a substantial radial system is installed, the radials themselves also make the best lightning ground. By "substantial" I mean at least 15 or so eighth wavelength or longer; one or two radial wires regardless of length will offer little lightning protection OR RF ground effectiveness. Due to its nature as a short-duration pulse, lightning acts more like RF than like DC or 60~ a.c., and lightning grounds should be designed accordingly. Don k4kyv _______________________________________________ _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |