To: | towertalk@contesting.com |
---|---|
Subject: | Re: [TowerTalk] Force 12 loading coils |
From: | Roger D Johnson <n1rj@roadrunner.com> |
Date: | Mon, 04 Jan 2016 12:36:29 -0500 |
List-post: | <towertalk@contesting.com">mailto:towertalk@contesting.com> |
I measured my XM-240 coils with a TS-617 Q meter and Q of about 160. It's quite
difficult to get a decent
connection from the Q meter to the coil. Any R in the connections is seen as
lower Q.
73, Roger## Check this out. http://www.qsl.net/ve6wz/coil.htm and http://www.qsl.net/ve6wz/CC_coil.html The Cushcraft XM240 12 ga magnet wire coils wound on solid fiberglass only have a Q of 81..which is piss poor. 10 ga would be slightly better. Jim VE7RF _______________________________________________ _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk _______________________________________________ _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |