Towertalk
[Top] [All Lists]

Re: [TowerTalk] Rohn 25 Guying

To: towertalk reflector <towertalk@contesting.com>
Subject: Re: [TowerTalk] Rohn 25 Guying
From: N1BUG <paul@n1bug.com>
Date: Sun, 27 Dec 2015 14:41:31 -0500
List-post: <towertalk@contesting.com">mailto:towertalk@contesting.com>
We did the same with a 50 foot and later 100 foot repeater tower, except our trees were a little smaller and anchors just above ground level. I never like it but it was our only option at the time. Happily it has since been converted to a tower guyed straight out of current Rohn specifications, with a bit of overkill on the size of the anchor blocks.

Paul



On 12/25/2015 07:04 PM, Wayne Kline wrote:
Tom

the  "TREE" guy anchor is no where in any ROHN  installation book
I am aware of. With that said. YES we hams do some unorthodox
things. I my self have two 100' lay over Rohn towers ,  will not
find a " Rohn falling Deric design" in any book. As for tree guy
anchor points. When Our club had it's  2 meter  repeater it was
120' of Rohn 25 guyed to THREE  36 " diameter  oak trees/ the guy
point was 100' out and 7 foot up from the ground. They drilled a
through hole  and used a threaded power line  guy anchor . and on
the back side a 4" square plate and two nut's one to tighten and
one to lock. lasted 30 plus yeas till a  cell tower site replaced
it !!!   Only problem was at the end  the tree  was getting close
to the 4 way equalizer plate eye/bolt  1/2 left  ,soon minimizing
any movement .

YMMV

Wayne W3EA