>> Not with just "any network analyzer", like the 8711; you need a 4 port
>> network analyzer, such at the Agilent E5071C with 4 port option.
>>Isn't there a process (perhaps tedious and manual) to do this with a 2 port
>>analyzer?
An affordable solution is the VNWA. It’s only a 2-port VNA, but its application
includes calculations for 3-port measurements. As I recall, DG8SAQ included
that specifically for baluns. Users say it works great for this particular
application (I don’t have personal experience with this instrument; I have an
N2PK VNA, and wrote my own code for it).
Gary, NA6O