Date: Mon, 26 Oct 2015 12:31:56 +0000
From: john nistico <electric911inc@hotmail.com>
To: "towertalk@contesting.com" <towertalk@contesting.com>
Subject: [TowerTalk] More 40 meter problems
I do not have a tower at the moment. I have a hustler 5 btv that was on my roof
but now it is ground mounted. For some reason when I get on 40 it trips one of
my arc fault breakers. I replaced the troubled breaker with the same results. I
am a master electrician and saw this with one of my GFI outlets but when I
changed it the problem stopped. This has not and I do not want to put a regular
breaker in its place as it would not be safe. Any Ideas?
NY6DX
## You could also stack two corcoms, nose to tail. Like the other fellow
mentioned, they may have leakage,due to caps, if a pi filter used.
You could also try type 31 ferrite...and wind the hot + neutral over the
ferrite. Im sure k9yc will chine in on this. It’s the only way I can stop
from tripping my 5 x motion detector lights from going off.
Jim VE7RF
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
|