To: | "TowerTalk@contesting.com" <TowerTalk@contesting.com> |
---|---|
Subject: | Re: [TowerTalk] Recommendations for an electric foldover winch |
From: | Ralph Bolt via TowerTalk <towertalk@contesting.com> |
Reply-to: | Ralph Bolt <robolt@yahoo.com> |
Date: | Fri, 1 Aug 2014 10:23:52 -0700 |
List-post: | <towertalk@contesting.com">mailto:towertalk@contesting.com> |
Rick: The motor shaft is 1/2 inch diameter. You mistook the size of the keyway for the shaft size. The motor develops 1/9 HP which when geared down from it's approximate motor speed of 1600 rpm to the 10 rpm out of the gearbox easily develops the 500 inch-pounds of torque. It's a very hefty motor and gearbox. Nominal current draw by the nameplate is 3.6 amps. I put my clamp-on ammeter on it while raising the tower and it drew just 3.0 amps. So the motor is not overtaxed. Ralph, K0HML _______________________________________________ _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: [TowerTalk] Recommendations for Purchasing a short 2 Element 40 Meter, James C. Hall, MD |
---|---|
Next by Date: | Re: [TowerTalk] TowerTalk Digest, Vol 139, Issue 51, David Gilbert |
Previous by Thread: | [TowerTalk] Recommendations for Purchasing a short 2 Element 40 meter beam, James C. Hall, MD |
Next by Thread: | Re: [TowerTalk] Recommendations for an electric foldover winch, Richard (Rick) Karlquist |
Indexes: | [Date] [Thread] [Top] [All Lists] |