To: | towertalk@contesting.com |
---|---|
Subject: | Re: [TowerTalk] 75 or 70 Ohm twinlead or ladderline cable - does it exist? |
From: | Steve Hunt <steve@karinya.net> |
Date: | Wed, 26 Mar 2014 14:43:40 +0000 |
List-post: | <towertalk@contesting.com">mailto:towertalk@contesting.com> |
Jim,I forgot to say that the line distributed parameters - R, L, G and C - are all directly calculable from Zoc and Zsc; to that extent you can then calculate the losses associated with R as distinct from those associated with G. But of course the moment we talk about R, L, G and C we are assuming the line behaviour can be modelled a certain way ;) Steve G3TXQ _______________________________________________ _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |
Previous by Date: | Re: [TowerTalk] 75 or 70 Ohm twinlead or ladderline cable - does it exist?, Steve Hunt |
---|---|
Next by Date: | Re: [TowerTalk] TowerTalk Digest, Vol 135, Issue 40, K7LXC |
Previous by Thread: | Re: [TowerTalk] 75 or 70 Ohm twinlead or ladderline cable - does it exist?, Jim Lux |
Next by Thread: | Re: [TowerTalk] 75 or 70 Ohm twinlead or ladderline cable - does it exist?, Rick Stealey |
Indexes: | [Date] [Thread] [Top] [All Lists] |