Towertalk
[Top] [All Lists]

Re: [TowerTalk] Fwd: Welding Rebar

To: "Roger (K8RI) on TT" <k8ri-on-towertalk@tm.net>, "towertalk@contesting.com" <towertalk@contesting.com>
Subject: Re: [TowerTalk] Fwd: Welding Rebar
From: Wayne Kline <w3ea@hotmail.com>
Date: Mon, 6 Jan 2014 13:50:24 -0500
List-post: <towertalk@contesting.com">mailto:towertalk@contesting.com>
I think we all have a  few OMG or WTF regarding tower/antenna   installation 
and upkeep
 
Field  Day.  are a prime example of  Elmer's rule ( If it did not fall down it 
was not big enough or high enough )
 
I personally know of a statin that had 5 towers 4 100' & 1 80'  guyed with 3/16 
ehs three levels on the 100' and two levels on the 80
all with mono band beams  one being a full size 40 meter beam and there  were 
screw in anchor's and NO  I repeat NO concrete
anywhere . the bases being Rohn 25 hinge  plates   bolted to 2' X 3' steel 
plate and a three or four rebar's 1/2 dia pounded in the soft wet ground.. last 
for many many many years
 
  YMMV
 
 Wayne W3EA    
 
 
Date: Mon, 6 Jan 2014 03:26:43 -0500
> From: K8RI-on-TowerTalk@tm.net
> To: towertalk@contesting.com
> Subject: Re: [TowerTalk] Fwd:  Welding Rebar
> 
> On 1/6/2014 12:58 AM, Hans Hammarquist wrote:
> > I believe K2TTT put one tower up using nothing as a base, just the tower 
> > standing on a small plate, resting directly on ground. Yes, it is (was) 
> > guyed.
> Over the years (since 61) I've had 7 towers up using dirt bases. They 
> were only 40-50' with one 60 footer, and one 90 footer, all guyed.  I 
> had a 5L 20M KLM, 6L 15M KLM,(42' booms) and a 7L Wilson 10M Yagi on a 
> 39' boom. One was 90' with a Cushcraft ATB34  It's a rather rugged dirt 
> base and in solid soil, I'd not hesitate to go 90 feet with 25G, but 
> avoid those towers that only have the horizontal bracing.   
> http://www.rogerhalstead.com/ham_files/Dirt_Base.htm  I'd consult an 
> engineer for higher or different soil.  I over guyed the 90 footer which 
> was a mistake.  The extra weight and proper tension of the larger steel 
> guys put an excessive vertical load on the tower causing the bottom 3 
> sections to bell out where they join, requiring a hydraulic jack to get 
> them apart.
> 
> 73
> 
> Roger (K8RI)
> 
> >
> > Dave, am I correct?
> >
> >
> > Hans - N2JFS
> >
> >
> 
> 
> ---
> This email is free from viruses and malware because avast! Antivirus 
> protection is active.
> http://www.avast.com
> 
> 
> _______________________________________________
> 
> 
> 
> _______________________________________________
> TowerTalk mailing list
> TowerTalk@contesting.com
> http://lists.contesting.com/mailman/listinfo/towertalk

                                          
_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk