Towertalk
[Top] [All Lists]

Re: [TowerTalk] from towers to shack

To: towertalk@contesting.com
Subject: Re: [TowerTalk] from towers to shack
From: john@kk9a.com
Date: Tue, 10 Dec 2013 07:13:33 -0500
List-post: <towertalk@contesting.com">mailto:towertalk@contesting.com>
The Array Solutions protectors use MOVs with a capacitor across them.

John KK9A



To:     towertalk@contesting.com
Subject:         Re: [TowerTalk] from towers to shack
From:    Jim Lux <jimlux@earthlink.net>
Date:    Mon, 09 Dec 2013 21:57:57 -0800

On 12/9/13 9:00 PM, GARY HUBER wrote:
Here's another MOV solution;
http://www.arraysolutions.com/images/SurgeSupressorManual_1.pdf .....
simply (8 or 16) 65 volt MOVs in a NEMA box. I mounted the 16 terminal
version at the ground window and cable entrance of my shack. The ground
window is bonded to the tower ground system on the outside and is also
bonded to the supplemental and primary system electrical ground systems
in accordance with the National Electrical Code. For coaxial cables, I
use bulkhead connectors to penetrate the ground window (aluminum plate ,
Plexiglas / plastic , aluminum plate sandwich) with ICE co-axial
protectors;
http://www.arraysolutions.com/ManualsandAppNotes/AS-3xxManual.pdf



Doesn't say those are MOVs.. with a 65V firing voltage, those could be gas
discharge tubes.

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>