Thanks all.
I now know what I need to do.
jim ab3cv
On Tue, Oct 8, 2013 at 6:32 AM, Steve Hunt <steve@karinya.net> wrote:
> Jim,
>
> That's correct - otherwise you are providing a path for CM current that
> bypasses the choke.
>
> 73,
> Steve G3TXQ
>
>
>
>
> On 07/10/2013 21:13, Jim Miller wrote:
>
>> I'm getting ready to mount my beam atop my AB621. My location is the
>> highest for a couple of miles around the trees here are often hit by
>> lightning.
>>
>> I'm planning to ground my coax at the top and bottom of my tower and of
>> course bond it at the utility entrance on the way to the shack.
>>
>> Am I correct that the common mode choke should go between the top-of-tower
>> ground and the rotor loop on the way to the beam? To do otherwise would
>> seem to just short it out.
>>
>> Thanks
>>
>> Jim ab3cv
>> ______________________________**_________________
>>
>>
>>
>> ______________________________**_________________
>> TowerTalk mailing list
>> TowerTalk@contesting.com
>> http://lists.contesting.com/**mailman/listinfo/towertalk<http://lists.contesting.com/mailman/listinfo/towertalk>
>>
>>
>>
> ______________________________**_________________
>
>
>
> ______________________________**_________________
> TowerTalk mailing list
> TowerTalk@contesting.com
> http://lists.contesting.com/**mailman/listinfo/towertalk<http://lists.contesting.com/mailman/listinfo/towertalk>
>
>