Towertalk
[Top] [All Lists]

Re: [TowerTalk] blown 10m section of ICE419 again - N1NK comments

To: <TOWERTALK@contesting.com>
Subject: Re: [TowerTalk] blown 10m section of ICE419 again - N1NK comments
From: <john@kk9a.com>
Date: Thu, 3 Oct 2013 01:18:05 -0000
List-post: <towertalk@contesting.com">mailto:towertalk@contesting.com>
I do not recall this article, however I have read a number of complaints on 
contesting.com about blown 10m sections with the ICE filters.  FWIW, I have 
had good lucking with Dunestar bandpass filters and I am sure that the W3NQN 
filters are even better.

John KK9A



To:<towertalk@contesting.com>
Subject:[TowerTalk] blown 10m section of ICE419 again - N1NK comments
From:"Jim Spears"
Date:Wed, 2 Oct 2013 20:06:00 -0400

Read the recently published QST review of bandpass filter boxes.  The ICE is
definitely "fragile" at 100 watts going into it at any swr.



Jim/N1NK

To:<towertalk@contesting.com>
Subject:[TowerTalk] blown 10m section of ICE419 again
From:"WW3S"
Date:Wed, 2 Oct 2013 18:15:47 -0400

Both ICE 419 filters blew the 10m side again....both were already repaired
using the CDE 1000v series caps from Mouser, one had 2 270 pf in, and the 
other
had 3 180 pf.....the one with 2 blew almost right away, the one with 3 
lasted a
2-3 hours maybe....running just 100w into a Cushcraft A4 with what appears 
to
be low enough SWR.....before I order again from Mouser, any ideas?

73, Jamie WW3S 