How about four of these:
http://www.mouser.com/ProductDetail/Cornell-Dubilier/CDV16FF131JO3/?qs=sGAEpiMZZMtLiKaZgV7flU44AUKbBD%2fXW8YQ%2f4vnaRY%3d
Dave Hachadorian, K6LL
Yuma, Arizona
-----Original Message-----
From: WW3S
Sent: Wednesday, October 02, 2013 3:15 PM
To: towertalk@contesting.com
Subject: [TowerTalk] blown 10m section of ICE419 again
Both ICE 419 filters blew the 10m side again....both were already
repaired using the CDE 1000v series caps from Mouser, one had 2
270 pf in, and the other had 3 180 pf.....the one with 2 blew
almost right away, the one with 3 lasted a 2-3 hours
maybe....running just 100w into a Cushcraft A4 with what appears
to be low enough SWR.....before I order again from Mouser, any
ideas?
73, Jamie WW3S