>     Guyed towers are allowed to be out of plumb by  something like 
> 3-4" per 
> 100 feet. 
> Cheers & GL,
> Steve     K7LXC
> TOWER TECH 

That pretty much agress with the formula I posted yesterday:
H/360.  So, with a 100ft tower, the total deviation is 
100*12/360 = 3.3 inches.

73,
Charlie, N0TT