To: | K7LXC@aol.com,TowerTalk@contesting.com |
---|---|
Subject: | Re: [TowerTalk] misaligned vertical towers |
From: | Missouri Guy <n0tt1@juno.com> |
Date: | Fri, 22 Mar 2013 16:52:48 +0000 |
List-post: | <towertalk@contesting.com">mailto:towertalk@contesting.com> |
> Guyed towers are allowed to be out of plumb by something like > 3-4" per > 100 feet. > Cheers & GL, > Steve K7LXC > TOWER TECH That pretty much agress with the formula I posted yesterday: H/360. So, with a 100ft tower, the total deviation is 100*12/360 = 3.3 inches. 73, Charlie, N0TT _______________________________________________ _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: [TowerTalk] misaligned vertical towers, Grant Saviers |
---|---|
Next by Date: | Re: [TowerTalk] misaligned vertical towers, K1TTT |
Previous by Thread: | Re: [TowerTalk] misaligned vertical towers, K7LXC |
Next by Thread: | Re: [TowerTalk] misaligned vertical towers, K1TTT |