The guy specifications are the manufacture's recommendation. Certainly many 
other configurations are possible with proper engineering.  I had a 70 foot 
tower in Aruba for a decade and two the elevated anchors were only 35 feet 
from the base.  How far out can you install your anchors?

John KK9A / P40A

To:<towertalk@contesting.com>
Subject:[TowerTalk] Rohn 25 guying question
From:"Gregg W6IZT" <gregg.w6izt1@gmail.com>
Date:Fri, 15 Mar 2013 16:35:42 -0400
List-post:<towertalk@contesting.com">mailto:towertalk@contesting.com>

I am planning to put up 130 ft. of Rohn 25 to be used as a 160 meter
vertical. There will be no antennas on this tower. The Rohn spec for guy
anchor points is 80% or 104 ft.



I am looking for some guidance. Getting 3 guy points each at 104 ft. from
the tower is going to be challenging due to terrain and property lines. Are
there any guidelines for anchor placement for a tower that does not have to
be subjected to additional loading from an antenna?



Any feedback is greatly appreciated.



73