Towertalk
[Top] [All Lists]

Re: [TowerTalk] connecting more than one stubs

To: towertalk@contesting.com
Subject: Re: [TowerTalk] connecting more than one stubs
From: David Robbins <k1ttt@verizon.net>
Reply-to: k1ttt@arrl.net
Date: Wed, 21 Nov 2012 09:27:45 -0600 (CST)
List-post: <towertalk@contesting.com">mailto:towertalk@contesting.com>
yes, you can connect all the stubs for a band to a single T connector.  The 
diagram shows space between them but that is not necessary.  the only one where 
spacing is important is the 40m combination of 15'3" and 7'8" MUST be connected 
to the same T or very close together, the drawing shows a barrel connector, but 
they can just be connected to a T.


Nov 21, 2012 08:20:38 AM, sv1dpi@otenet.gr wrote:

David tnx for quick reply. Ok with the switch and i can trim the stubs 
for the switch's length but can i connect more than one stub in one 
T-connector? To make that clear i have a switch with 4 positions. Can i 
switch at position 1 for 10m and have there both 23' and 11' stub 
connected? That would be perfect but i am not sure if it is ok...
73 Kostas sv1dpi