| >  That's it.  Many years ago I installed a Glenn Martin  70' aluminum tower
which used 4000I philly and used cable  clamps. 
 
    That was probably in the days before the Big Grips  were available. 
Using cable clamps on the Phillystran led to cold-flow of the  aramid fibers 
and a reduction in strength - a big problem. But you weren't  tensioning them 
to the 400# you'd need for regular guys so your risk exposure  was pretty 
small. 
 
Cheers,
Steve    K7LXC
TOWER TECH
_______________________________________________