Towertalk
[Top] [All Lists]

Re: [TowerTalk] 13.8 dc tower protection

To: towertalk@contesting.com
Subject: Re: [TowerTalk] 13.8 dc tower protection
From: Jim Lux <jimlux@earthlink.net>
Date: Sun, 22 Jul 2012 15:26:14 -0700
List-post: <towertalk@contesting.com">mailto:towertalk@contesting.com>
On 7/22/12 8:29 AM, johne tds.net wrote:
> I need to --build-- not BUY some type of lighting damage reduction for
> the  13.8 volt DC running to antenna switching. I did have a link that
> no longer works of some information. I would like to use some MOV's
> and inductors / and or other --to drain off the near  junk.
>
> Looking for any diagrams and inductor sizing  information. Have been
> pursing the web , Just not finding the link or info.
>
> Thanks de John KØCQW
>

Rather than a MOV, what you really want is a big power zener.  The MOV 
dies a little each time it clamps.  The Zener keeps on ticking.  So put 
a reverse biased 20V (or whatever you feel comfortable with) Zener 
across it, and that will clamp nicely.

And an inductor in series to reduce the speed of the transient will also 
reduce coupling from the circuit with the transient to other adjacent 
circuits.
_______________________________________________