On 4/28/2012 8:40 PM, TexasRF@aol.com wrote:
> does anyone know what size conductors are needed for a 500ft
> cable used with a G1000SDX rotator?
>
> Yaesu simply says use #18 if over 125ft.

There are five conductors. I did an interpolation of their stupidly 
vague recommendation in the manual, translating it to 2.5 ohms max 
resistance in the loop that runs the motor, which is pins 4 and 5. I 
made a note that #14 is sufficient for 525 ft. Much greater resistance 
is acceptable for the three conductors (pins 1, 2, and 3) that go to the 
500 ohm pot that senses position. #18 would be a very conservative choice.

It's overkill, but I used two  twisted triplets of #14 house wiring for 
the 350 ft run to my Yaesu rotator.  While the outer jacket is not 
particularly robust, It will probably last longer than i will, and 
because it is sold in such great quantities, can be bought cheaper than 
smaller stuff that would work fine.

73, Jim K9YC