On 4/16/2012 3:54 PM, Bob Ad5vj wrote:
> I was always told to use flat braid for station grounds in years past for RF 
> purposes and if you didnt have any, make it from coax braid.

Actually braid is NOT a good choice for bonding grounds outdoors, 
because it corrodes so quickly.   The better choice is wide flat copper 
ribbon -- it lowers inductance a bit (but ONLY a bit) as compared to a 
round conductor of equivalent cross section, and doesn't corrode as 
quickly as braid.