OK, so under 24v for the most part.
Thanks
Chris
On Oct 11, 2011, at 21:28 , K0DAN wrote:
More or less +/- 12-20 VDC, and in the real world it seems to be pretty
flexible. Typical caveats of voltage drop on long & high resistance runs. The
"speed" control on the SDX/DXA controllers varies the motor voltage. The rotor
seems pretty tolerant: think 33 RPM vinyl disk for your HF array!
73
k0dan
-----Original Message----- From: EZ Rhino
Sent: October 11, 2011 10:03 PM
To: Tower and HF antenna construction topics.
Subject: [TowerTalk] Yaesu rotator line voltage?
Does anyone know what the control line voltage is on Yaesu rotators?
Chris
KF7P
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
|