The back pressure of blowing air through a conduit
requires an air pump as opposed to a fan,
especially a muffin fan. A small aquarium air pump
might work.
Rick N6Rk
On 4/30/2011 12:51 PM, Clint Talmadge W5CPT wrote:
> I am about to add a couple of antennas and the idea of burying conduit for
> the coax and control cables came up again. The stories of water collecting
> made me think of how to avoid this. What if I were to add a small fan to
> the box to which I am going to hang on the outside wall of the shack to
> which I am going to connect the conduit? This fan would pressurize the
> ambient air which should eliminate any standing water in the system. A
> small shroud to keep out the direct rain should be sufficient. Small
> screened weep holes in the boxes at the tower base and the box for the
> phasing network for the verticals would allow any moisture in the
> pressurized air to escape. The fan, being outside should not cause any
> objectionable noise. I am thinking of something along the lines of a larger
> muffin fan which will run off house power fed out through the conduit
> installed through the wall.
>
>
>
> I have tried to come up with any negatives, but have not (yet). Any ideas,
> positive or negative on this plan?
>
>
>
> Clint - W5CPT - West Kentucky
>
>
>
> _______________________________________________
>
>
>
> _______________________________________________
> TowerTalk mailing list
> TowerTalk@contesting.com
> http://lists.contesting.com/mailman/listinfo/towertalk
>
>