On 9/12/2010 8:08 PM, Anthony J. Cioffi (N2KI) wrote:
> Anyone know where to get LMR400 coax grounding kits at good price?
>
>
I just use bulkhead connectorw and heavy Aluminum Angle saddleclamped 
across a face of the tower to the tower legs at both the top and bottom 
of the tower.

With larger coax I'd go with the grounding kits as they are far cheaper 
than the connectors for those sizes. OTOH those same grounding kits are 
much more expensive than a bulkhead connector and a pair of PL-259s or N 
connectors with it being close to a wash for the 7-16 connectors for the 
ones I've looked at.

However, from the home brew point you only need some copper flashing, 
and water proofing along with some SS hose clamps.