Hi Anthony. Simply specify the required psi when ordering concrete and let them 
know to have the driver bring empty concrete test canisters (two for each 
truckload) with him. Do not pour without the test canisters! This gives the 
concrete company incentive to give you the proper mix. Don't rely on slump...it 
is too qualitative. Then in 30 days have an independent local lab test one 
canister from each load. 

Best regards, 
Scott W3TX

On Sep 1, 2010, at 8:51 AM, "Anthony J. Cioffi \(N2KI\)" <n2ki@amsat.org> wrote:

> Guys,
> 
> 
> 
> Tomorrow is the next step in my tower installation. Concrete is being poured 
> tomorrow.  My question is what slump should I
> use?  It is 4000psi. 
> 
> 
> 
> Pictures of the installation are uploaded here.
> (http://picasaweb.google.com/109109461434829776230/N2KISTowerInstallation?authkey=Gv1sRgCKjzp8rAo7jNzwE
> <http://picasaweb.google.com/109109461434829776230/N2KISTowerInstallation?authkey=Gv1sRgCKjzp8rAo7jNzwE&feat=directlink>
> &feat=directlink )
> 
> 
> 
>   Thanks for your help.
> 
> 
> 
> 
> 
> Anthony - N2KI
> 
> 30MDG - 1187
> 
> www.n2ki.com
> 
> 
> 
> 
> 
> 
> 
> _______________________________________________
> 
> 
> 
> _______________________________________________
> TowerTalk mailing list
> TowerTalk@contesting.com
> http://lists.contesting.com/mailman/listinfo/towertalk
_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>