When I was in the navy we used a powdered graphite lubricant to prevent
galling.
David Robbins K1TTT
e-mail: mailto:k1ttt@arrl.net
web: http://www.k1ttt.net
AR-Cluster node: 145.69MHz or telnet://dxc.k1ttt.net
> -----Original Message-----
> From: Grant Saviers [mailto:grants2@pacbell.net]
> Sent: Friday, June 25, 2010 02:54
> To: towertalk@contesting.com
> Subject: Re: [TowerTalk] anti seize/never seize ?
>
> Passivated SS, which is frequently the case for machine screw sizes (<
> 1/4-20) is much less likely to gall. Passivation tends to make the
> screws more gray in color and less shiny.
>
> Lanolin is also a "standard" anti gall lubricant for SS and is packaged
> for this purpose and is a lot less messy than anti-seize compounds. I
> doubt there is much difference (magic) among the various anti-seize
> brands, it seems they have pretty much the same metal powders in a
> grease base, as long as the proper formulation is chosen for the
> materials being fastened.
>
> Grant KZ1W
>
> Jim Thomson wrote:
>
> snip
>
> > Funny thing is.. I use SS machine screws all the time on HB amps... [
> like 10-32 1/4-20, 8-32 6-32 etc] and have never had a
> > gauling problem with em in the last 20 yrs. The gauling problem only
> seems to happen with 3/8" and bigger.. and esp when
> > SS nylocks are employed.
> >
> > I hope this anti seize/never seize goop actually works. Trying to cut
> rusted /gauled hardware..up a tower is no fun.
> >
> > Later..... Jim VE7RF
> > _______________________________________________
> >
> >
> >
> >
> >
> _______________________________________________
>
>
>
> _______________________________________________
> TowerTalk mailing list
> TowerTalk@contesting.com
> http://lists.contesting.com/mailman/listinfo/towertalk
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com