Towertalk
[Top] [All Lists]

Re: [TowerTalk] Andrew 1 5/8 hardline

To: "Tower and HF antenna construction topics." <towertalk@contesting.com>
Subject: Re: [TowerTalk] Andrew 1 5/8 hardline
From: Steve Maki <lists@oakcom.org>
Reply-to: "Tower and HF antenna construction topics." <towertalk@contesting.com>
Date: Fri, 09 Apr 2010 21:33:51 -0400
List-post: <towertalk@contesting.com">mailto:towertalk@contesting.com>
John,

VXL7 cable needs "V7" connectors. The various Heliax cables have 
different center conductor diameters because of the different dielectric 
properties. I believe I have some V7 connectors if you need them.

For ham use there is no functional difference between LDF7, AVA7, and 
VXL7 coax - whatever you can get for a good price and get connectors for.

I have a fair amount LDF7 and AVA7 in stock at a good price, with lots 
of 7/16 DIN female connectors, and a few N connectors...Detroit area.

-Steve K8LX


john@kk9a.com wrote:
> I am very familiar with Andrew LDF7-50A 1 5/8 Heliax, but often I see other 
> model cables such as VXL7-50, for a reasonable price.  The specs seem 
> similar, except there's mention of it being  flexible.   Is anyone familiar 
> with VXL-50?  Do the LDF7-50A connectors fit or are special connectors 
> needed and are there any disadvantages to using the cable?  Any comments are 
> appreciated.
_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk