Thanks Skip, I appreciate your time and experience.
73,
Ron W8RJL
----- Original Message -----
From: <KJ6Y@aol.com>
To: <towertalk@contesting.com>
Sent: Friday, March 26, 2010 11:34 AM
Subject: Re: [TowerTalk] LM-354 Tower Base Bolts
> Ron,
> Most cases they were A307 Grade 5 3/4" bolts. In rare cases they used
> A325 High strength bolts. They required being torqured to 350 ft/lbs. If
> you
> have the engineering calcs, it should say in them. If you go with the
> A325, they require a Registered Deputy Inspector watch you torque the
> bolts.
>
> Skip, KJ6Y
> _Communications Service Co_ (http://www.communicationsserviceco.com/)
> 22712 Califa St
> Woodland Hills, CA 91367
> 818-887-3569