For my 350-400' runs I use belden 9405 (2x16+6x18) and parallel the extra
18ga wires with the 16's. 2 motors draw 5-6a so I think the extra copper is
worth it.
David Robbins K1TTT
e-mail: mailto:k1ttt@arrl.net
web: http://www.k1ttt.net
AR-Cluster node: 145.69MHz or telnet://dxc.k1ttt.net
> -----Original Message-----
> From: Scott Dickson [mailto:w5wz@w5wz.com]
> Sent: Wednesday, February 24, 2010 03:16
> To: towertalk@contesting.com
> Subject: [TowerTalk] Tic Ring control cable sizing
>
> I see the owner's manual suggests 18 ga wire will work up to 400 for
> single
> motor and 300 ft for 2nd and 3rd motors.
>
>
>
> Does real world experience agree with this, or should I upsize the wire
> for
> good measure?
>
>
>
> --Scott, W5WZ
>
> _______________________________________________
>
>
>
> _______________________________________________
> TowerTalk mailing list
> TowerTalk@contesting.com
> http://lists.contesting.com/mailman/listinfo/towertalk
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
|