Al Williams wrote: > cool off but I wonder if that is necessary. Is the load on the brake > winch > less now that I have four pulleys instead of two in the cabling system so > that it won't heat up as much? > > k7puc Instead of counting pulleys, count the number of cables supporting the load. If there are N cables, the load on the cable is 1/N of the total pull. Rick N6RK _______________________________________________ _______________________________________________ TowerTalk mailing list TowerTalk@contesting.com http://lists.contesting.com/mailman/listinfo/towertalk |