Rick Karlquist wrote:
>> off being taped or strapped to a tower leg every few feet. You
>> certainly don't want it hanging by the connectors and 110 feet is a lot
>> of load for one of the cable hangers.
> I have a number of coax and control cables hanging from my 106 ft
> crank up tower by Kellums grips. Seems to work fine.
Most cables are fine up to about 200' hanging from a kellum or hoisting
grip if they are protected from the wind, as they would be in a PVC
tube, cellular monopole, or held laterally by crankup tower standoffs.
But I certainly wouldn't go to the trouble of running PVC tube up a
tower for UV protection.