Tom,

No, the connectors are not interchangeable.  

Andrew L5 connectors use a self-tapping inner contact, while V5 connectors use 
a captive inner contact.

The VXL5 jacket diameter is slightly smaller (27.5 vs 28 mm), while the VXL5 
inner conductor diameter is slightly larger (9.42 vs 9.0 mm).

73
Frank