Towertalk
[Top] [All Lists]

[TowerTalk] Wiring an LM70 Motor..

To: <towertalk@contesting.com>
Subject: [TowerTalk] Wiring an LM70 Motor..
From: "Bill Winkis" <kc4pe@bellsouth.net>
Date: Wed, 26 Nov 2008 17:42:47 -0500
List-post: <towertalk@contesting.com">mailto:towertalk@contesting.com>
The tower is a TrEx LM-70 with postive up and down....

I have the direct replacement motor from Leeson, #102908 ..... but the motor 
wiring has changed....

The new motor has the following info on the motor label......:

-A single Wire Labeled P1 which is "Line 1"
-A single Wire Labeled P2 which is "insulate"
-Two wires tied together ..... Labeled T4 and a second wire labeled T5 which is 
"Line 2"
-Three wires tied together labeled t2 & T3 & T8 which is "Insulate" 

.................................................................................................................................

My TriEx manual , using a picture of the motor says 
Wire P1  - Gets the Green wire from controller
Wire T8 - (Hard to Read) Looks like White wire from controller
Wire T5- (Hard to Read) Looks like the Red wire
Wires T2 & T4 (Are Tied Together) Looks like the Black wire 
Wires P2 andd T3 are joined together and does not get a wire from the 
controller....

Any body make heads or tails out of this...

-Bill
kc4pe@bellsouth.net