The tower is a TrEx LM-70 with postive up and down....
I have the direct replacement motor from Leeson, #102908 ..... but the motor
wiring has changed....
The new motor has the following info on the motor label......:
-A single Wire Labeled P1 which is "Line 1"
-A single Wire Labeled P2 which is "insulate"
-Two wires tied together ..... Labeled T4 and a second wire labeled T5 which is
"Line 2"
-Three wires tied together labeled t2 & T3 & T8 which is "Insulate"
.................................................................................................................................
My TriEx manual , using a picture of the motor says
Wire P1 - Gets the Green wire from controller
Wire T8 - (Hard to Read) Looks like White wire from controller
Wire T5- (Hard to Read) Looks like the Red wire
Wires T2 & T4 (Are Tied Together) Looks like the Black wire
Wires P2 andd T3 are joined together and does not get a wire from the
controller....
Any body make heads or tails out of this...
-Bill
kc4pe@bellsouth.net
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
|