In a message dated 10/29/2008 7:07:32 A.M. Pacific Daylight Time,  
towertalk-request@contesting.com writes:

>  I just obtained a used MA550 self supporting, crankup  tower.? It's 10 
years old and never been used.? I'm thinking I should change  the cable before 
putting it up so I called US Tower to ask for cable  replacement instructions.? 
However, they refused citing liability issues.?  They will however sell a 
replacement cable for $213.00.
 
    First, tower manufacturers are insurance-driven  enterprises. They're not 
about to give you any real information because of  liability exposure issues. 
 
    There are 3 reasons why you'd need to replace  your cables. 1: Excessive 
broken strands (around 6-8 as I recall). 2: Damage -  flattened or kinked. 3: 
Rust - real rust, not surface rust. I suspect that  your cables probably don't 
need replacing. 
 
    If you really want to, the tower has to be  horizontal and you have to 
extend the tower fully to start re-cabling it. I  understand it's not a bad job 
- pretty straightforward. 
 
    There isn't much in the way of PM that you can  do. You can lubricate the 
exposed cable once or twice a year and that'll be  good. 
 
    I've always thought that these are aesthetically  nice towers.
 
Cheers,
Steve     K7LXC
TOWER TECH 
 
Cheers & GL, 



 
**************Plan your next getaway with AOL Travel.  Check out Today's Hot 
5 Travel Deals! 
(http://travel.aol.com/discount-travel?ncid=emlcntustrav00000001)
_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>