Re: [TowerTalk] {SPAM} Re: hazer comments

To: "Dan Hearn" <dhearn@air-pipe.com>, "Dennis Petrich" <radioart@charter.net>, <WB4UNA@aol.com>, <TowerTalk@contesting.com>
Subject: Re: [TowerTalk] {SPAM} Re: hazer comments
From: "WA3GIN" <wa3gin@comcast.net>
Date: Wed, 30 Jul 2008 21:43:31 -0400
List-post: <towertalk@contesting.com">mailto:towertalk@contesting.com>
Don't do it unless the tower is designed for guying...some are! The TRI-EX 
CT-100 is a crank-up designed to be guyed. Each tower section carries the 
weight of those above it. Not a problem for the 1/4" steel cables. The dead 
weight antenna spec is 600lbs and the wind load spec is 40sq ft fully 
extended.  Over 25yr old, never had a problem...I check the cables at least 
twice a month if not weekly.

Good Luck,
dave
wa3gin

----- Original Message ----- 
From: "Dan Hearn" <dhearn@air-pipe.com>
To: "Dennis Petrich" <radioart@charter.net>; <WB4UNA@aol.com>; 
<TowerTalk@contesting.com>
Sent: Wednesday, July 30, 2008 9:05 PM
Subject: Re: [TowerTalk] {SPAM} Re: hazer comments


> Dennis: You will find different opinions here on many subjects however I
> believe there is almost uniform opinion on guying crankup towers. Don't do
> it. That puts additional stress on the lifting cables when horizontal 
> force
> is applied to the tower.  73. Dan, N5AR
>

> 