Earlier this year (a few weeks before he became a SK), I did some
maintainence work for N4UH.
Three of his six towers had served ends on some of the Crosby-clipped EHS
guy wires. ALL of those cables had rusted quite badly--the served ends
of the cable had very clearly trapped moisture over their 30 year life,
enough so that the cable was in need of replacement, or 2 - 3 feet of it
was anyway.
Henry was impressed when I installed StrandLinks & a new "end" of EHS.
And he really liked the Preformed Guy Grips! A few weeks later I was
dismantling the entire station....
vy 73 Don K4ZA