>Hello I am looking for some info if possible, I am building a rotor control
box
>for a light duty rotor I have here , and I am basing my design on a Ham 2
>Series of Rotor made By CDE. The questions I have are as follows...
>Question #1 What is the full scale defection rating of the meter in a CDE
rotor
>control box, I.E. 100micro amps
The meter movement is 1 mA.
> #2 Does anyone know what the output voltage is for the meter
>transformer as show in schematics found in the manual? There is no
indication
>of secondary voltages shown in the schematic.
The controller provides 13 VDC to the feedback pot.
Let me know if you have any more questions.
Ed