Towertalk
[Top] [All Lists]

[TowerTalk] RG6 compression connectors

To: towertalk@contesting.com
Subject: [TowerTalk] RG6 compression connectors
From: Craig Clark <jcclark@wildblue.net>
Date: Sat, 19 Jan 2008 10:36:46 -0500
List-post: <mailto:towertalk@contesting.com>
Just a thought but make sure you are not using quad shield connectors 
on dual shield cable. A properly installed connector on the 
appropriate RG6 should be a rock solid installation. Quad shield 
connectors on dual shield cable is a problem. I found that one out 
the hard way.

I'm using 3 GHz dual RG6 on my KD9SV bi-directional Beverages and 
Gilbert compression connectors that are used in the satellite TV and 
internet world.

Its getting "wicked" cold and the connectors are still firmly in place.

Flooded RG6 can be either dual or quad shield and it is my 
understanding that the coax does not require a special 
connector.......I have not used one for the flooded cables I have made.




73, Craig Clark, K1QX


RADIOWARE AND RADIO BOOKSTORE
PO  BOX 209
RINDGE NH 03461
603 899 6957
WWW.RADIO-WARE.COM