The 25G is a self-supporting tower up to 35 feet, according to the Rohn
Catalog. I did a minimal installation for a 35 foot tower as you described,
due to municipal restrictions, but in retrospect I wish I had made a bigger
hole for more concrete for possible future extension. I would suggest that,
if anything, you try to use more concrete in the base and since it's only 5
feet more than what Rohn recommends, you might be ok without guys - assuming
you don't put up a monster antenna or have lots of wind and ice.
73, Dave, WA0TTN
> -----Original Message-----
> From: towertalk-bounces@contesting.com [mailto:towertalk-
> bounces@contesting.com] On Behalf Of Tim Heger
> Sent: Sunday, November 11, 2007 3:05 PM
> To: TowerTalk@contesting.com
> Subject: Re: [TowerTalk] Installation Rohn 25G
>
> Does the last line in your message, "No guy wires at this point in time",
> mean that you intend to use the tower unguyed?
> It needs to be guyed. 25G isn't self supporting tower.
>
> 73, Tim - N3XX
_______________________________________________