Towertalk
[Top] [All Lists]

Re: [TowerTalk] hanging Heliax

To: richard allen <rca@rcallen.com>, towertalk@contesting.com
Subject: Re: [TowerTalk] hanging Heliax
From: Hardy Landskov <n7rt@cox.net>
Date: Wed, 17 Oct 2007 08:46:06
List-post: <mailto:towertalk@contesting.com>
Richard,
I use cushion clamps from Air-Tech Inc. I use the CL2010S for my LDF4-50A
coax. They provide a very snug gripping action without crushing the coax. I
paid $0.30 a piece. You will have to research what clamp is right for the
LDF5. Go to www.air-techinc.com
I would stay away from hose clamps and tie wraps rot in the sun especially
here in AZ.
73 Hardy N7RT

At 05:51 PM 10/16/2007 -0500, richard allen wrote:
>I am about to install two runs of 7/8 Heliax (LDF5) and three of 1/2 
>Heliax (LDF4) going up a 55 foot tower. 
>
>Can I use hose clamps to secure the cable?
>
>Can I use lots of heavy plastic tie wraps (1/2" wide)?
>
>Can I use the hose clamps around the connector for grounding at the 
>top or do I need to use the Andrews grounding kits?
>
>Any suggestions would be appreciated.
>
>Thanks,
>
>Richard W5SXD
>_______________________________________________
>
>
>
>_______________________________________________
>TowerTalk mailing list
>TowerTalk@contesting.com
>http://lists.contesting.com/mailman/listinfo/towertalk
>
_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk