If you can remove the cables, and being that you are not already
familiar with cable crimping, and the fact that one small mistake
could cause your tower to fail, I'd take the cables off and have them
done professionally by a local wire cable vendor. They will have the
correct cable (made to roll over sheaves, usually 7x19 wire rope) and
the correct tools to properly crimp the ends.
Go to...
http://www.mcmaster.com/
type "1341" in the search box and read about 7X19 cable (NOT 19X7!)
The tools and sleeves are on page "1352".
Good Luck!
At 10:01 PM 9/5/2007, Harry Williams wrote:
>I have a Hygain HG-70D crankup tower and have been thinking about
>replacing the cable. The tower is down right now and it does not
>appear to be a very difficult process to replace the cable. I see
>that the cable ends are held in place by a pair of crimped on
>clamps. Where can I get the clamps and what kind of tool is needed
>to do the crimping?
>
>73's,
>Harry
>W0LS
>_______________________________________________
>
>
>
>_______________________________________________
>TowerTalk mailing list
>TowerTalk@contesting.com
>http://lists.contesting.com/mailman/listinfo/towertalk
>
>
>
>--
>No virus found in this incoming message.
>Checked by AVG Free Edition.
>Version: 7.5.485 / Virus Database: 269.13.5/990 - Release Date:
>9/4/2007 10:36 PM
>
>
>
>
>--
>No virus found in this incoming message.
>Checked by AVG.
>Version: 7.5.485 / Virus Database: 269.13.5/990 - Release Date: 9/4/2007
Dino - K6RIX
dino@k6rix.com
--
No virus found in this outgoing message.
Checked by AVG.
Version: 7.5.485 / Virus Database: 269.13.5/990 - Release Date: 9/4/2007
_______________________________________________
_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
|